This high-performance, fast, professional & portable ultrasonic flaw detector adopts square wave technology to meet diverse needs. It perfectly combines excellent performance with unique features—boasting fast response, digital-simulated experience and anti-interference capability. It detects flaws (including welding flaws) as precisely as your "sixth sense," serving as a practical portable detection workstation.
Measuring range:1.0~15000mm
Resolution:0.01mm(<100mm) 1mm(>100mm)
Velocity:500~2000m/s (20 fixed sound velocity)
Display delay:-20~3400us resolution: 0.1us
Probe delay:0~99us
Resolution:0.01us
Auto calibration:Measurement and setting of sound velocity and probe delay using two known calibration echoes (2-point calibration )
Linear error:Horizontal linearity error≤0.1%
Vertical linearity error:≤3%
Dynamic range:≥36dB
Sensitivity:leavings ≥64dB 200mmФ2 flat-bottomed hole
Dimension:240×180×50mm
Weight:1.9Kg(including battery pack)
Working environment:Temperature: 0℃~60℃
Humidity:20%~90%
Transmission Pulse:
Drive Pulse:Negative pulse/Square Wave
Pulse Width:50~2000ns
Pulse Amplitude:50-500v
Damping:50/150/250/400Ω
Testing mode:Pulse echo/ transmitting and receiving /transmission
Measuring mode:Peak /Verge
Gain:0 to 110dB
Customers define steps:0/0.2/0.5/1/2/6/12
Detector Pattern:RF/full-wave/positive /negative half- wave
Frequency bandwidth:0.3~1 / 0.5~4 /2~15MHz broad band filter 1/2.5/5/10/15 MHz narrow band filter
Display:LCD Wide temperature high-light TET color LCD 5.7" industrial class
Display refresh frequency:Not less than 60Hz
GUI theme:5 GUI color themes: simple/classical/gray/bright light/ dark light, Customers could choose theme by setting color of characters,A wave scan,coordinate color,background
Gate:Two separated gates A/B
Storage:Channel parameters 20 groups
A-scan wave:3,200 group
Thickness value:320,000,linear
Reference wave:4
Probe cable:LEMO/BNC
Communication:RS232/USB
Language:English
Power adapter:Input 100~240V/50~60Hz /Output 9VDC/4A
DAC curve:3D calibration point can be recorded; automatic gain; arbitrary order calibration; calibration/editing two correction methods; material attenuation and surface compensation factors are considered;
DGS curve:suitable for three reference types of large flat bottom, flat bottom hole and through hole. Reference attenuation, material attenuation and surface compensation factors are considered. Defect evaluation method: equivalent size/equivalent gain/percentage.